CR # Description Comment
53741

The System Architect documentation did not contain information about a limitation with creating workspaces. The limitation is that you cannot create workspaces on encyclopedias residing on SQL Server 2000.

Do not attempt to create workspaces on encyclopedias residing on SQL Server 2000. The related help files and Release Notes have been updated with this limitation and are now available in the Rational System Architect Information Center (updated September 30, 2009).
52565

The 'System Architect Process Integrator Installation Guide' contained an erroneous command which would fail to install the SAService.exe as given. On page 6 of the guide, the incorrect command line option is:

SystemArchitectXT_11.3.exe /V"SAPI_SERVER="Yes""

The correct command line option is:

SystemArchitectXT_11.3.exe /V"SAPI_SERVER=\"Yes\""

Use the correct command line above at left. You can also find this information in the 'System Architect Process Integrator Installatoin Guide' on the Rational System Architect Information Center (updated August 10, 2009).
47780 System Architect Catalog Manager inappropriately lets users delete a Workspace that is active, or in use by System Architect users. When this occurs, a System Architect dialog displays a ‘Database error’ and System Architect sessions using the deleted Workspace end abnormally. To avoid this problem, users of System Architect Catalog Manager should ensure no one is using a Workspace before deleting it.
48016 In System Architect, when you have a Baseline Workspace open, and attempt to create a new encyclopedia, you are unable to create the new encyclopedia, and the following message is displayed: 'The read-only version cannot create a new encyclopedia path. Please open an existing path.’ To prevent this error, do not attempt to create an encyclopedia while you have Baseline Workspace open. Instead, consider, shutting down and restarting System Architect, or open a non-Baseline encyclopedia before attempting to create a new encyclopedia.
48037  If System Architect shuts down abnormally when you have diagrams opened, the auto-recovery feature inappropriately displays the ‘Select Workspace’ dialog and enables you to select a Workspace, which makes it possible for you to select an incorrect Workspace. Ensure that you select the correct Workspace. Doing so allows the auto-recovery feature to recover and open your diagram(s). 
48701 The speed at which Dynamic Views open in the Explorer is slower on all Views other than the ‘All’ Views. The ‘All’ Views opens at optimum speed, while other Views do not. You can use the ‘Classic Explore’ instead of the ‘Explorer’ for optimum performance.
49954 Information is lost when you change UML 2 diagram contents in a Workspace encyclopedia, where diagram is keyed by a parent Workspace Avoid creating UML 2 diagrams in enyclopedia Workspaces as this feature is not yet supported. 

46771

Using an encyclopedia's display name when you open it through the API can be noticeably slower than opening the encyclopedia through a connection string. If opening an encyclopedia through an API, do not use the encyclopedia’s display name. Use connection strings instead.
47461 The following error message is displayed when you uninstall Rational System Architect XT through the ‘Add or Remove Programs’ window: ‘Component not registered.’ Click ‘OK’ in the error dialog and continue to uninstall the product.
49986 When you attempt to merge or extract encyclopedia objects from a baselined Workspace, and you select the ‘All Changes’ option, the objects fail to be merged or extracted. Do not use the ‘All Changes’ option. Instead, use the ‘Selected Changes’ option to merge or extract successfully.
47887 When using the sym.Penstyle or sym.Linestyle in a VBA macro to modify the symbol, the settings do not get applied. For example, using ‘sym.PenStyle = PENSOLID4’ does not work. Do not use the sym.Penstyle or sym.Linestyle. As an example, use the following code instead ‘sym.SetField SYMFLD_PENSTYLE, PENSOLID4.’
47924 If you customize the installation of System Architect so that System Architect Catalog, System Architect Encyclopedia Manager (SQL Server) or System Architect Encyclopedia Manager (Oracle) are not installed, and you then install System Architect Encyclopedia XT over that customized installation, the shortcut icons for those components are not added to the Start menu. The shortcuts should be added because Rational System Architect XT uses those components to manage users and encyclopedia access. You can create shortcuts to launch the components and add them manually to the Start menu, Desktop, or elsewhere.

50286

In the Rational System Architect - Rational Focal Point integration, System Architect fails to display attributes in the Focal Point attributes list. The problem only occurs while you are editing an existing Profile in System Architect.

Since the issue does not occur while you are creating a new Profile in System Architect, a workaround this issue is to create a new Profile after new attributes have been added in Focal Point.

50435

Focal Point allows duplicate names for Workspaces. This makes it possible for System Architect to export data to the wrong Focal Point Workspace. For example, if you have two same-named Workspaces and delete one of them, System Architect allows you to export to the Workspace still present, even though this may not be the correct Workspace.

A possible workaround is to avoid creating Workspaces with the same name in Focal Point.

49649

Previous Root Workspace history values are displayed under the current child Workspace column. For example, suppose you create definition ‘A’ in a Workspace named Root, and baseline the Root Workspace. You then create a Workspace named WS2, from the Root baseline. If you open Workspace WS2, and view definition ‘A’ in the History window, the Workspace column incorrectly displays WS2. It should display Root, the Workspace in which the definition was created.

There is no workaround for this issue.

47930

When you create or modify a diagram property where the LENGTH value is 40000 or higher, in the diagram property dialog, the label for that property is displayed, but you cannot enter data into the field.

Do not create or modify properties where the LENGTH value exceeds 40000.

47981

When you customize the installation of the System Architect Process Integrator for Visio 2003 or Visio 2007, and choose an installation path other than the default, the installation still creates the default installation path, with a duplicate of the “SetSecurity.InstallState” file.

 

48097

When you install System Architect to a custom folder, then install System Architect XT over that custom installation, an additional ‘System Architect Suite’ folder is created.

All System Architect XT files are created in the location where System Architect is installed

48157

When you update a definition property using the ‘Advanced Edit’ feature, the update is not shown in the Property pane, even if you selected ‘Yes’ to refresh the Explorer.

You can click the 'Refresh' option to view property updates.

48293

The ‘Undo’ button becomes disabled when you apply a color scheme to any of the following diagram types: Class, State, Business Process, Organization Chart, Network Concept, Enterprise Direction, or Physical Data Model.

 

48307

If you uninstall System Architect XT when it has been installed over System Architect, a message box stating “Users shall not be able to use SAXT” is displayed, but the message box displayed out of focus, behind the ‘Add or Remove Programs’ dialog.

 

48374

In System Architect Catalog Manager, no warning message is displayed when changes are made to the Users or Roles on an encyclopedia that has been enabled with the ‘Published Optimized XT Reader Views’ (also known as Libnet).

Users should be notified that hanges to their roles on an encyclopedia enabled with the ‘Published Optimized XT Reader Views’ have been made.

49687

The 'Optimize XT Reader Views' do not get updated in System Architect Catalog Manager when you add permissions.

For permissions to be updated, you have to exit System Architect Catalog Manager, reopen it, and click on the 'Publish Optimized XT Views' menu option.

48630

When you import an XML file of an Entity Relationship Diagrams containing 2 entity symbols, but only one of them has a definition, both entity symbols are imported into the repository. Only one entity symbol is shown on the diagram, but a Delete Diagram preview shows tow entities.

A workaround for this issue is to move one the entity symbol shown on the diagram, and save the diagram. Afterwards, only the entity shown on the diagram is shown on the Delete diagram preview.

49044

The OV-5 diagram is not autorefreshed after after you branch ICOMS.

 

49969

System Architect Process Integrator files are installed directly into the ‘C:’ drive without any folder being created.

 

48503

It is not possible to move packages across packages by dragging them in UML tab.

 

49826

The System Architect Explorer is not refreshed when you pressing the F5 key.

 

49973

Incorrect message - Auto-Arrange Left to Right without save.

 

50460

Incorrect stylesheet for lines on Business Process diagram.

 

50630

System Architect XT is not able to log into a Workspace-enabled encyclopedia.

 

50204

‘Generate User Prop..’ option not functioning in baseline enabled encyclopedia.

 

50289

The Edit button in the property pane is improperly enabled for a baselined (read only) encyclopedia.

 

50535

System Architect Encyclopedia Manager (Oracle) displays an internal code error after you delete an encyclopedia in Oracle database.

 

51906 While trying to open an encyclopedia with Rational System Architect 11.3, an error message similar to the following may be displayed: “Unprintable char at line#12: at char position# 27." The workaround for this issue is to delete the ‘solnprops.cfg’ file in the temp folder. Additionally, you should modify the ‘solnprops.cfg’ file in the encyclopedia so that either a blank line or a comment is the last line in that file. To do this, you have to export the ‘solnprops.cfg’ file, modify it (as described above), and import it back into the encyclopedia. See the Rational System Architect online help for information on the temp folder and modifying files in the encyclopedia.

 


Fixed Problems

For details of problems that have been resolved in Rational System Architect V11.3, view the Whatsnew.htm file provided in the C:\Program Files\IBM\Rational\System Architect Suite\11.3\System Architect directory.


Contacting Support

Please visit our Telelogic support overview site at: http://www.ibm.com/software/rational/support/telelogic/
You will find a one-sheet reference guide about how to best contact support in your geography.


Notices

This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service.

IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not grant you any license to these patents. You can send written license inquiries to:

IBM Director of Licensing
IBM Corporation
North Castle Drive
Armonk, NY 10504-1785
U.S.A.

For license inquiries regarding double-byte character set (DBCS) information, contact the IBM Intellectual Property Department in your country or send written inquiries to:

IBM World Trade Asia Corporation
Licensing
2-31 Roppongi 3-chome, Minato-ku
Tokyo 106-0032, Japan

The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law:
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions. Therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.

Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk.

IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Licensees of this program who wish to have information about it for the purpose of enabling: (i) the exchange of information between independently created programs and other programs (including this one) and (ii) the mutual use of the information which has been exchanged, should contact:

Intellectual Property Dept. for Rational Software
IBM Corporation
1 Rogers Street
Cambridge, Massachusetts 02142
U.S.A.

Such information may be available, subject to appropriate terms and conditions, including in some cases, payment of a fee.

The licensed program described in this document and all licensed material available for it are provided by IBM under terms of the IBM Customer Agreement, IBM International Program License Agreement or any equivalent agreement between us.

Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.

Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products.

This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental.

If you are viewing this information softcopy, the photographs and color illustrations may not appear.

Trademarks

IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at Copy and Trademark information at www.ibm.com/legal/copytrade.html.

Adobe, the Adobe logo, PostScript, and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries.

IT Infrastructure Library is a registered trademark of the Central Computer and Telecommunications Agency which is now part of the Office of Government Commerce

Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.

Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.

Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both.

ITIL is a registered trademark, and a registered community trademark of the Office of Government Commerce, and is registered in the U.S. Patent and Trademark Office

UNIX is a registered trademark of The Open Group in the United States and other countries.

Cell Broadband Engine is a trademark of Sony Computer Entertainment, Inc. in the United States, other countries, or both and is used under license therefrom.

Java and all Java-based trademarks and logos are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.

Other company, product or service names may be trademarks or service marks of others.