Rational DOORS version 9.2 Known Problems
IBM Corporation
02 June, 2009

This file contains details of known problems in IBM® Rational® DOORS® 9.2 (Rational DOORS).

It is divided into the following sections:

Attributes
Change Proposal System
Clone Modules
Cut, Copy and Paste
Discussions
Exporting
External Links
Generate Support Request
Importing
In-Place Edit
Installation
Integrations
Licensing
Linking
Localization
Location
Miscellaneous
TDS Migration
User log on
Views
Welcome screen





For the latest news and information on Rational DOORS, visit the Rational Software Support site.

back to top


Attributes

Defect Number Summary Workaround
30171 Create a new attribute in a module, then edit the attribute and clear the Inherit from parent check box on the Access (Value) tab and click OK. Select the new attribute and click Edit. Select the Access (Value) tab and select any user or group in the list. The Remove and Edit buttons are unavailable and the access rights can't be edited. Select and clear the Inherit from parent check box. The Remove and Edit buttons will be available until you close the dialog box.


back to top


Change Proposal System

Defect Number Summary Workaround

The 'From' line in email messages sent from the Change Proposal System may display Japanese characters as question marks (?). The problem is reported in the Microsoft Knowledge Base article: http://support.microsoft.com/default.aspx?scid=kb;en-us;324603. This contains information that may help resolve this issue.


back to top


Clone Modules

Defect Number Summary Workaround
19919 In a formal module, create an attribute and include a ? (question mark) in the attribute name. Filter the module on this attribute, and save the filter in a view. Clone the module, selecting the filter view, and the 'Columns' check box. A DXL error is displayed, and the clone is incomplete. Remove the question mark from the attribute name before you clone the module.


back to top


Cut, Copy and Paste

Defect Number Summary Workaround
28902 If two users are pasting objects from one place to another at the same time a "paste failed: lock request timed out" error message is displayed. Wait and redo the paste.


back to top


Discussions

Defect Number Summary Workaround
30329 If there are unsaved changes to an object in a module, you can start a new discussion on a different object, but you can't save that discussion. You have to cancel the discussion and save the module then start the discussion again. Make sure you save the module before you start a new discussion.


back to top


Exporting

Defect Number Summary Workaround
20228 If you resize an OLE Object that has been inserted in DOORS using Insert > OLE Object, then export the OLE object to Word, the OLE is displayed in Word at its full size. This is because Word controls the OLE size, not DOORS. None.
20294 Export a DOORS module to Microsoft Word in Table format, and select 'Ignore DOORS column widths in table layout export, AutoFormat instead'. Any bold characters in the object text of the module are not bold in the export. None.
25550/26278 You cannot export embedded OLE objects to PowerPoint 2007. Copy the whole of the doors object into the clipboard and then paste it into the PowerPoint presentation.
25809 If you export a module to Word that contains objects with URLs that include braces ({}), the export will not be successful. If the module contains objects with URLs that include braces ({}), export to RTF instead.
26803 If you create a new template in Word, and import it into DOORS before you save it, there will be a VB 5151 runtime error. Always save new Word templates before you import them into DOORS.
27314 If you try to export to html a module with links, and you do not have access to one or more of the modules that are linked to, a DXL error will be displayed and the module will not be exported. You need to have access to the all of the target modules.


back to top


External Links

Defect Number Summary Workaround
28491 Citrix only
The default browser in DOORS when using Citrix does not allow you to open any external links.
In DOORS, select Tools > Options, then select the Settings tab. In the Web Browser field, change the location to something more appropriate for Citrix (perhaps E: or M:).


back to top


Generate Support Request

Defect Number Summary Workaround
32287 There is no Japanese translation for the Generate Support Request tool. None.
32426 When using Generate Support Request for the first time, if the user ICN number is not available to enter in the dialog, the user cannot continue or cancel the dialog. Enter a temporary ICN number and manually update the number at a later date.


back to top


Importing

Defect Number Summary Workaround
22127 If you import a table object as an OLE object from Word 2003,
two instances of the OLE object are imported.
None.
26916 If you import an RFT with auto-numbering, DOORS inserts a tab space between the Object Number and Object Heading. None.


back to top


In-Place Edit

Defect Number Summary Workaround
17493 In a module that has an enumerated attribute displayed in a column, double-click to in-place edit object text, then double-click to edit an enumerated attribute, then double-click to edit the object text again. It may appear that both attributes are in editable state. When you type, text is entered into the object text, but when you click away from the object text you have edited, the edit is lost. Changes to the enumerated attribute are not lost. None.


back to top


Installation

Defect Number Summary Workaround
28878 There can be occasions when you cannot install the DOORS Client after you have installed the DOORS Database Server. Install the DOORS Client before you install the DOORS Database Server.
29011 If Japanese characters are included in the Program Files path when installing the DOORS Database Server and the DOORS Client, the DOORS Database Server cannot be uninstalled. Uninstall the DOORS Client first.
29554 If you uninstall the DOORS Database Server and then the DOORS Example Data, the DOORS Server folder is not removed from the registry. Uninstall the DOORS Example Data before you uninstall the DOORS Database Server.


back to top


Integrations

Defect Number Summary Workaround
  Telelogic Rhapsody Integration
If you install Telelogic Rhapsody after you install DOORS, the video capture button in the Generate Support Request dialog box causes a run-time error.
Install Telelogic Rhapsody before you install DOORS.
  Telelogic Rhapsody Integration (2434)
If you include an attachment when you use the Generate Support Request option, and you have included an attachment in a previous request, the old attachment is included along with the new attachment.
Delete the file supportZip.zip from C:\Documents and Settings\username\Local Settings\Temp\zipAttach folder before you send the new request.
14971 Rose Integration.
If you try any of the Rose based DRL operations (Send to DOORS, Update DOORS and Find in DOORS) without having DOORS open then DRL will attempt to start it.
This leads to the DOORS login screen appearing alongside a DXL interaction window. The errors may refer to a file "C:\Temp\drlcmds" and may also refer to "incorrectly concatenated tokens" or an "undeclared variable".
Open DOORS before trying to perform operations from Rose to DOORS
15478 Rose Integration.
If you select an item in DOORS try to use the find "Find in DOORS" function while the desired object is in an open module, it may appear that nothing has happened. The correct filter has been applied but the module has not been given focus.
Bring module to front to see filtered objects
15870 ClearQuest Integration
If you run more than one DOORS session using the same DOORS client on a machine, you can only run ClearQuest Integration in one of the DOORS sessions. If you attempt to run ClearQuest Integration in a second session using the same DOORS client, DXL errors are generated, and the connection to the ClearQuest database is lost.
None.
21364 ClearQuest Integration
Renaming the ClearQuest defect record type is not supported by ClearQuest.
To see details of this known problem on the IBM Support Site click here
None.
23981 TestDirector Integration
If you initiate synchronization from DOORS, then stop the TestDirector server before the synchronization is complete, the synchronization status does not report that the TestDirector server has been stopped.
Do not stop the TestDirector server when synchronization is in progress.
26824 TestDirector Integration
When you install TestDirector Integration with DOORS 8.3 there is a problem with IAS configuration.
After you've installed the Integration Server, you need to
make the integration available for IAS configuration.

1. Create the following folder:

C:/Documents and Settings/Default User/Application Data/Telelogic/DOORS/Dictionary.

2. Set the access permissions for the
C:/Documents and Settings/Default User/Application Data/Telelogic folder:

a. Navigate to C:/Documents and Settings/Default User/Application Data/Telelogic and right-click Properties.

b. Select the Security tab and click Add.

c. Enter ASPNET, click Check Names, then click OK twice.

3. Select the ASPNET user and select Full Control.

4. Click OK.


back to top


Licensing

Defect Number Summary Workaround
29342 If you don't provide any license information during installation, you will not be able to start DOORS without creating an environment variable. Create a user-defined environment variable called TELELOGIC_LICENSE_FILE.

1. Right-click My Computer, and select Properties then the Advanced tab.

2. Click the Environment Variables button.

3. Click New, and enter a valid path to the license server (19353@license_server_name).

DOORS can now access a license and successfully launches.

29423 If all the licenses have already been checked out and you try to borrow a license, you cannot see you've been unsuccessful or the reason without changing the size of the Borrow Status column. You can do this by dragging the top right-hand corner of the column but it is not apparent that this is possible. Resize the column.


back to top


Linking

Defect Number Summary Workaround
24864 If you use the Create Links tool to create a link between two modules, and you have read-only access to the target module, which is not currently open, the Raise button on the Create Links dialog box does not open the target module. Open the target module manually before creating the link.


back to top


Localization

Defect Number Summary Workaround
31290 System attributes are not translated when using a localized system. None.
31596 The File > Print dialog is not fully translated when using a localized system. None.
31399 The File > Baseline > View > Signatures > Configure tab may not be displayed when using a localized system. None.
31398 The Database Administration tool is not translated on localized systems. None.
31675 The File > Module Properties > History tab is not fully translated in the Only Show Entries With section None.
31392 Spelling checker message are not translated when using a localized system. None.
32504 When you install DOORS on a Japanese locale, choosing Japanese characters in the installation path results in a non-localized version of DOORS displayed. When you install the Rational DOORS client in Japan, you must accept the default location.


back to top


Location

Defect Number Summary Workaround
29967 If the clipboard is not empty, you can't copy text from the Location field in the DOORS Database Explorer. Select Edit > Clear in the DOORS Database Explorer before you copy text in the Location field.


back to top


Miscellaneous

Defect Number Summary Workaround
28299 Citrix only.
Select Tools > Options, then select the Settings tab. In the Web Browser field, the final double-quotes (") has been omitted from the default location. This is resulting in errors.
Add the final double-quotes (") manually.
29933 Equations copied and pasted from Word 2007 are pasted as static images and are not editable. Insert the Equation in Word by selecting Insert > Object, then selecting Microsoft Equation 3.0 from the list.


back to top


TDS Migration

Defect Number Summary Workaround
32578 DOORS ACLs are not preserved when migrating users from standalone TDS 3.0 to RDS 5.0. None.
32586 Migrated users will not be able to log on to DOORS after migrating from standalone TDS 3.0 to RDS 5.0. None.


back to top


User log on

Defect Number Summary Workaround
31646 When a Linux DOORS Database Server is configured to use a secure port, the two-factor authentication feature does not function. None.


back to top


Views

Defect Number Summary Workaround
29183 If a view inherits its access rights, and you follow links to objects in that view, the default module view is loaded in error. Load the view manually.


back to top


Welcome Screen

Defect Number Summary Workaround
29603 If you select or clear the Show Welcome Screen at start-up option, navigate away from the Welcome Screen without closing, and exit the DOORS Explorer, the change is not stored. Close the Welcome Screen after you select or clear the Show Welcome Screen at start-up option.


back to top